MP48

The RTU, based on ITACO-MP48 technology,  is designed to be able to offer products, systems and integrated solutions for every application in the industrial, infrastructure, residential and utilities fields. The clear criticality of the application and the characteristics of the environments in which these devices heve to work, requires special care in  all stages of production, from design to installation and start-up. For this reason we have achieved very stringent quality goals of our product: high modularity, high performance, reliability certified by accredited laboratories, specifically engineered testing procedures. From the hardware point of view, quality of each product is guaranteed by 32-bit CPU, while, as regards the software, by the LinuxRT operating system and by components implementing the IEC 60870-5 (101, 103, 104 both client and server) protocol family, by the IEC 61850 protocol and by Modbus protocol (master and slave). The processor can also implement programmable logic according to IEC 61131 and to set up an HMI panels framework, programmable with graphic design software.

  • embedded real time Linux OS

  • acquisition of simple or multiple digital signals, analog or digital measures, energy pulses

  • commands and set-point management

  • time synchronization with time server via NTP network protocol and / or GPS receiver module that can be installed  on board

  • management of SNMP protocol

  • millisecond temporal resolution of the events

  • communication via dedicated cable networks, switched networks, radio, fiber, WiFi, GSM / GPRS, ADSL, frame relay

  • multiple connections to multiple supervisory centers management with different communication protocols

  • master-slave configurations for local areas

  • optional remote installation of the I / O  modules

  • Integrated web server for remote viewing of data, states, log, parameters

  • inclusion of local and distributed logic using the IEC 61131 standard logical operators

  • COMTRADE files storage and transmission

  • ability to connect to intelligent field devices (PLCs, controllers, IEDs, etc.) via field bus with standard IEC 60870-5-101, IEC 60870-5-104 protocols, Modbus, IEC 60870-5-103, IEC 61850, etc

  • local memory log with programmable events cancellation  logic based on the earliest date or on memory space (1 million events per 100 Mbytes of memory)

Fill out the form to request more information